Measuring Accuracy¹:
± 1% of reading
Zero Stability:
0.45 kg/h, 0.0165 lb/min
Mass Repeatability:
± 0.5% of reading
Temperature Accuracy:
±1.8 °F ±0.5 % of reading, (±1 °C ±0.5 % of reading)
liquid Flow Rates:
@ 850 kg/m3, pressure drop max 2 bar:
180 kg/hr @ 1 cSt (6.6 lbs/min @ 1 cSt) | 150 kg/hr @ 10 cSt (5.5 lb/min @ 10 cSt) | 65 kg/hr @ 30 cSt (2.4 lb/min @ 30 cSt)
Gas Flow Rates:
@ 20C air, pressure drop 10 bar:
394 kg/hr @ 1050 bar (14.5 lbs/min @ 15,200 psi) | 362 kg/hr @ 690 bar (13.3 lb/min @ 10,000 psi) | 316 kg/hr @ 414 bar (11.6 lb/min @ 6000 psi
@ 20C H2, pressure drop 50 bar:
254 kg/hr @ 1050 bar (9.3 lbs/min @ 15,200 psi) | 240 kg/hr @ 875 bar (8.8 lb/min @ 12,690 psi) | 222 kg/hr @ 690 bar (8.15 lb/min @ 10,000 psi) | 184kg/hr @ 414 bar (6.75 lb/min @ 6000 psi)
Pressure RatingS:
15,200 psi, 1050 bar
10,000 psi, 690 bar
6000 psi, 414 bar
operating Conditions – Process
Gas/Liquid Temperature Range: -40°F to +212°F (-40°C to +100°C)
Liquid Temperature Accuracy: ±1.8°F ±0.5% of reading (±1.0°C ±0.5% of reading)
Gas Temperature Accuracy: ±0.9°F ±0.25% of reading (±0.5°C ±0.25% of reading)
Materials of Construction:
Tubes: 1.4404 / AISI 316L Stainless Steel or Sandvik Alloy HP160
Manifold: 1.4435/AISI 316L Stainless Steel
Housing: 1.4404 / AISI 316L Stainless Steel
EX Certifications:
CSA (US & Canada): Class I, Division 1: Groups A, B, C, D T2…T4
ATEX: Zone 1: Group IIC, T2…T4 | Zone 2: II 3G Ex nA IIC,T2…T4 Gc
IECEx: Zone 1: Group IIC, T2…T4
¹ Stated flow accuracy combines the effects of repeatability, linearity and hysteresis.