Flow: ± 0.5% of flow rate
Mass Repeatability: ± 0.1% of flow rate
Zero Stability: 0.45 kg/h (0.0165 lb/min)
Temperature: ±1.8°F, ±0.5% of flow rate (±1°C, ±0.5% of flow rate)
14.5 lbs/min @ 15,200 psi (400 kg/hr @ 1,050 bar)
13.3 lbs/min @ 10,000 psi (362 kg/hr @ 690 bar)
11.6 lbs/min @ 6,000 psi (316 kg/hr @ 414 bar)
TCMH 0450-HC-SPMS: 15,200 psi (1050 bar)
TCMH 0450-HC-SRMS: 10,000 psi (690 bar)
TCMH 0450-HC-SSMS: 6,000 psi ( 414 bar)
Process Temperature Range: -40 °F to +212 °F (-40°C to +100°C)
Medium: Gas
Pressure Effect on Sensitivity: 0.000014% / psi (0.0002% / bar)
Ambient Temperature Range: -40 °F to +158 °F (-40°C to +70°C)
Relative Humidity: max. 95%
Tubes: Sandvik Alloy HP 160
Case: 1.4404 / AISI 316L Stainless Steel
Flow Splitter: 1.4404 / AISI 316L Stainless Steel
For more detailed material information, see Technical Datasheet or individual product Spec Sheets.
Rupture Disk: G½”
Flow Meter: 3/8” Autoclave (standard), others available on request
Signal Cable Connection: Push-pull connector
CSA (US & Canada):
Sensor: Class I, Division 1: Group A, B, C, D, T2…T4
Transmitter: Class I, Division 1: Group A, B, C, D, T4
ATEX Zone 1:
Sensor: Group II 1G Ex ia IIC T4…T2 Ga
Transmitter: Group II 2(1)G Ex db (ia Ga) IIC T4 Gb
ATEX Zone 2: II 3G Ex nA IIC T4
IECEx Zone 1:
Sensor: Group II 1G Ex ia IIC T4…T2 Ga
Transmitter: Group II 2(1)G Ex db (ia Ga) IIC T4 Gb
EAC (TR-CU):
Sensor: 0Ex ia IIC T4…T2 Ga X
Transmitter: 1Ex d (ia Ga) IIC T4 Gb X
KGS (Korea):
Sensor: Ex ia IIC T4
Transmitter: Ex d (ia) IIC T4
¹ Stated flow accuracy combines the effects of repeatability, linearity and hysteresis.
Flow: ± 0.2% of flow rate
Mass Repeatability: ± 0.075% of flow rate
Zero Stability: 0.34 kg/h (0.012 lb/min)
Temperature: ±1.8°F, ±0.5% of flow rate (±1°C, ±0.5% of flow rate)
¹ Stated flow accuracy combines the effects of repeatability, linearity and hysteresis.
@ 850 kg/m3:
6.6 lbs/min @ 1 cSt (180 kg/hr @ 1 cSt)
5.5 lbs/min @ 10 cSt (150 kg/hr @ 10 cSt)
2.4 lbs/min @ 30 cSt (65 kg/hr @ 30 cSt)
TCMH 0450-HC-SPOS: 15,200 psi (1050 bar)
TCMH 0450-HC-SROS: 10,000 psi (690 bar)
TCMH 0450-HC-SSOS: 6,000 psi ( 414 bar)
Process Temperature Range: -40°F to +212°F (-40°C to +100°C)
Medium: Liquid
Pressure Effect on Sensitivity: 0.000014% / psi (0.0002% / bar)
Ambient Temperature Range: -40°F to +158°F (-40°C to +70°C)
Relative Humidity: max. 95%
Tubes: Sandvik Alloy HP 160
Case: 1.4404 / AISI 316L Stainless Steel
Flow Splitter: 1.4404 / AISI 316L Stainless Steel
For more detailed material information, see Technical Datasheet or individual product Spec Sheets.
Rupture Disk: G½”
Flow Meter: 3/8” Autoclave (standard), others available on request
Signal Cable Connection: Push-pull connector
CSA (US & Canada):
Sensor: Class I, Division 1: Group A, B, C, D, T2…T4
Transmitter: Class I, Division 1: Group A, B, C, D, T4
ATEX Zone 1:
Sensor: II 1G Ex ia IIC T4…T2 Ga
Transmitter: II 2(1)G Ex db (ia Ga) IIC T4 Gb
ATEX Zone 2: II 3G Ex nA IIC T4
IECEx Zone 1:
Sensor: II 1G Ex ia IIC T4…T2 Ga
Transmitter: II 2(1)G Ex db (ia Ga) IIC T4 Gb
EAC (TR-CU):
Sensor: 0Ex ia IIC T4…T2 Ga X
Transmitter: 1Ex d (ia Ga) IIC T4 Gb X
KGS (Korea):
Sensor: Ex ia IIC T4
Transmitter: Ex d (ia) IIC T4
MASS FLOW RATE: 14.5 lb/min
PRESSURE RATING: 15,200 psi | 1050 bar
CONNECTION: 3/8″ Autoclave
MASS FLOW RATE: 13.3 lb/min
PRESSURE RATING: 10,000 psi | 690 bar
CONNECTION: 3/8″ Autoclave
MASS FLOW RATE: 11.6 lb/min
PRESSURE RATING: 6,000 psi | 414 bar
CONNECTION: 3/8″ Autoclave
Wall mounted multi-variable Coriolis transmitter that can output flow rate, total, density or temperature.
With hazardous area approvals: CSA (US & Canada), ATEX, and IECEx.
Superior resistance to cracking caused by hydrogen
Allows custody transfer of Hydrogen in fueling operations
Allows pressures up to 15,200 psi
Can be used regardless of process pressure
Can be used in any safety classified area
For hydrogen fueling stations, TRICOR Coriolis Mass Flow Meters are installed directly in the dispenser, upstream of the heat exchanger to direct measurement of the mass flow and density of the hydrogen for billing and accurate dispensing. This setup eliminates undefined gas volumes in the pipe system and protects the flow meter from temperature gradients, ensuring accurate and reliable hydrogen measurement.
For hydrogen fueling stations, TRICOR Coriolis Mass Flow Meters are installed directly in the dispenser, upstream of the heat exchanger to direct measurement of the mass flow and density of the hydrogen for billing and accurate dispensing. This setup eliminates undefined gas volumes in the pipe system and protects the flow meter from temperature gradients, ensuring accurate and reliable hydrogen measurement.