Gear Meters

Gear meters specifically spur gear, are ideal for low flow rates, viscous fluids, and measurement of flows involving starts and stops or pulsing.

Variable Area Meters

Variable Area flow meters are a type of rotameter that measure oils, liquids or gases by relating linear displacement of an internal “float” or sharp-edged orifice plate to a corresponding flow rate.
Advanced flow meters with digital displays for precise liquid measurement.
High-accuracy flow meters with digital readouts designed for industrial fluid measurement.

Coriolis Mass Flow Meters

TRICOR Coriolis flow meters are highly accurate and repeatable multi-variable instruments that measure mass flow, density, and temperature with calculated volumetric flow and feature a very easy user interface.

Paddle Wheel Flow Meter

Operating much like a turbine flow meter, the paddle wheel flow meter consists of a freely rotating wheel which is outfitted with magnets on the blades or “paddles” of the wheel.

Helical Flow Meters

Helical gear ("screw-type") flow meters are designed for measuring highly viscous, abrasive, and filled fluids including lubricating and non-lubricating media, such as polyurethane, polymers, greases and oils.

Turbine Flow Meters

Axial turbine flow meters are designed with wear resistant internal components to provide trouble-free operation and a long service life in a wide variety of industrial applications.

Ultrasonic Flow Meters

Non-contact ultrasonic flow meters for accurate, instantaneous mass & volumetric flow rate measurement of clean, non-aerated fluids in full pipes such as water, chemicals, and oils.

Flow Electronics

Electronics coupled with our mechanical flow meters deliver flow data in your preferred format, whether a local display, remote transmitter, or simple pickup.

Rotary Piston

Rotary Piston positive displacement flow meters are ideal for use in applications with very low flow rates and high pressures, such as offshore chemical injection applications.

Turbidity Sensor

AW-Lake's ProScan Turbidity Sensor is ideal for detection of material transitions, monitoring turbidity, and measuring product concentration, such as in dairy processing, juice processing, and brewing operations.

Fluid Power / Hydraulics

Flow meters used to monitor flow readings in fluid power systems are essential to properly monitoring your process, diagnosing system errors, and ensuring system performance. Our expertise in this area goes back decades with numerous flow meters for the hydraulics and fluid power system industry.

Oil & Gas

From corrosive subsea environments, offshore production platforms, onshore oil fields, or refineries we have the flow expertise to tackle these tough jobs. Difficult oil and gas flow metering challenges like high pressures, pulsating flows, corrosive media and harsh environments are our daily business.

Heavy Industrial

For challenging industrial environments like mining, steel & paper mills, and industrial vehicles we offer flow meters with easy flow paths to run thick materials, rugged meter bodies that handle extreme conditions and designs with high shock and vibration resistance.

Paints/Sealants/Adhesives

Automotive plants and their Tier-1 suppliers have been using AW-Lake flow meters for 40+ years to monitor usage of paints, coatings, adhesives, lubricants, and other fluids to maintain strict process control and manage operational costs. Flow meters in these areas must be capable of measuring a wide range of materials.

Water Cooling

Monitoring process cooling systems, including industrial cooling circuits and HVAC systems, helps maintain your plant or building efficiency, conserve energy, and improve the bottom line. Constant monitoring and control of these systems can easily be done using flow monitoring and control instrumentation from AW-Lake.

General Industrial

General industrial plants around the world have been using AW-Lake flow meters to maintain their process operations, plus they have integrated our meters as a vital part of their end product. Our broad portfolio of flow measurement equipment provides solutions to your paint operations.

Test Systems

With increasing product complexity, tighter regulations, and growing demands on companies to reduce operating costs and improve product quality, there is more focus on test and measurement procedures and equipment.

Alternative Energy

As the world shifts towards sustainable practices, the demand for efficient energy production methods intensifies. AW-Lake flow meters are used in many ways within renewable energy sectors such as solar, wind, hydro, and biofuels.

Marine

In a field where fuel consumption attributes to most of the total operating costs, it is critical for marine ship owners and operators to monitor their fuel systems. Accurate fuel consumption is key to understanding how and where to find areas to improve efficiency and control costs.

Chemical

AW-Lake understands the challenges and intricacies of chemical / petrochemical process monitoring with flow meters. We have the depth of experience with corrosive, aggressive liquids and gases that you need in your flow measurement partner.

Environmental

As the the world continues to examine ways to lesson our impact on the environment and develop new technologies to support those efforts, flow measurement enters the conversation more and more.
Aircraft maintenance in aerospace industry.

Aerospace

AW-Lake flow meters are trusted in the aerospace and aviation industry, where they ensure precise measurement and control of fuel, hydraulic fluids, and other critical liquids and gases. They play a vital role in maintaining optimal performance, ensuring safety, and enhancing fuel efficiency.
Press Releases October 13, 2026

How to Perform a Beaker Test to Determine a Flow Meter K-Factor


A practical guide for checking pulse output against known collected volume

 

In many flow measurement applications, accuracy depends on one critical value: the meter’s K-factor. The K-factor defines the relationship between the number of electrical pulses generated by a flow meter and the actual volume of fluid that has passed through it. In simple terms, it tells a display, transmitter, PLC, or control system how to convert pulse output into a meaningful flow rate or totalized volume.

A beaker test is a practical field method for checking or determining a meter’s K-factor by comparing the meter’s pulse count against a known collected volume. While it does not replace a formal laboratory calibration when traceability is required, it can be a useful way to verify meter performance, troubleshoot a process, or confirm that a flow meter and its electronics are working together correctly.

Why the K-Factor Matters

A flow meter may be mechanically sound, properly installed, and generating a signal, but if the K-factor entered into the electronics is incorrect, the flow reading will also be incorrect. The K-factor is what allows the system to translate raw pulses into usable engineering units.
• Batch totals
• Dispensed volumes
• Flow rate displays
• PLC calculations
• Chemical feed rates
• Cooling loop monitoring
• Test stand results
• Process documentation and quality records

Even a small error can become significant in applications involving batching, dosing, lubrication, additive injection, test systems, or fluid usage tracking.

When to Perform a Beaker Test

A beaker test may be helpful when:
• A new meter is being installed and the user wants to verify its output.
• A meter has been cleaned, repaired, replaced, or reinstalled.
• The fluid being measured differs from the original calibration fluid.
• Operating conditions have changed, such as viscosity, temperature, pressure, or flow range.
• The displayed total does not match expected usage.
• A PLC, counter, transmitter, or totalizer has been replaced or reprogrammed.
• Operators suspect missed pulses, electrical noise, air in the line, or unstable flow.
• A quick field check is needed before deciding whether to send the meter out for formal calibration.

Professional calibration systems often rely on controlled gravimetric or volumetric standards to determine meter performance. A beaker test is much simpler, but the principle is similar: compare the meter output to a known reference quantity.

The Basic Formula

The K-factor is calculated as:
K-factor = Number of pulses / Actual volume collected

For example, if the initial pulse count is 12,450 pulses, the final pulse count is 22,510 pulses, and the collected volume is 10.00 liters, the pulse difference is 10,060 pulses.

K-factor = 10,060 pulses / 10.00 liters = 1,006 pulses/liter

If the system uses gallons, the collected volume must be recorded in gallons. If the system uses liters, the collected volume must be recorded in liters. The units must match the units expected by the display, PLC, transmitter, or totalizer.

Equipment Needed

• Flow meter under test
• Calibrated beaker, graduated cylinder, or volumetric collection vessel
• Fluid being measured
• Pump or another controlled flow source
• Flow meter display, counter, PLC, or data acquisition system capable of counting pulses
• Stopwatch or timer, if test duration or flow rate will also be recorded
• Appropriate tubing, fittings, and valves
• Spill containment
• Required PPE for the fluid and site conditions

The collection vessel should be accurate enough for the level of confidence required. A rough container may be acceptable for a simple functional check, but a calibrated volumetric vessel is recommended when the K-factor will be used for process control or calibration records.

Step by Step Beaker Test Procedure

1. Verify the Installation
Confirm that the flow meter is installed in the correct flow direction and that all tubing, fittings, and connections are secure. If the meter requires straight-run piping, full-pipe conditions, proper orientation, or a specific mounting position, confirm those requirements before testing.

2. Confirm the Pulse Output
Make sure the meter’s sensor, pickup, display, counter, or PLC input is operating correctly. If possible, record the existing K-factor currently programmed into the electronics so the new test value can be compared later. Confirm whether the receiving instrument expects pulses per unit volume or the reciprocal value, such as volume per pulse.

3. Use Representative Fluid and Conditions
For the most useful result, perform the test with the same fluid the meter will measure in service. Fluid properties such as viscosity, density, temperature, and entrained air can influence meter behavior, especially with mechanical flow meters.

4. Remove Air from the Line
Air bubbles can cause significant measurement errors. Run fluid through the system long enough to purge air from the line and fully wet the meter.

5. Stabilize the Flow
Start the pump or open the flow-control valve. Allow the flow rate to stabilize before collecting the test volume. If the meter will normally operate at a specific flow rate, perform the beaker test as close to that flow rate as practical.

6. Record the Initial Pulse Count
Before collecting fluid, record the initial pulse count shown on the display, counter, PLC, or data acquisition system.

7. Collect a Known Volume
Place the calibrated beaker or graduated vessel at the meter outlet so that all discharged fluid is captured. Continue until the desired test volume has been reached. A larger test volume generally produces a more reliable result because the effect of small timing or reading errors is reduced.

8. Stop Flow and Record the Final Pulse Count
Stop the flow as quickly and consistently as practical. Record the final pulse count, then calculate the pulse difference by subtracting the initial pulse count from the final pulse count.

9. Record the Actual Collected Volume
Read the actual volume from the calibrated vessel. Use the correct units and read the vessel at eye level to reduce parallax error.

10. Calculate the K-Factor
Divide the pulse difference by the actual collected volume. This produces the K-factor for that test run.

11. Repeat the Test
Perform at least three runs under the same flow conditions. Calculate the K-factor for each run, then calculate the average. If the results are repeatable and within the required tolerance, the average K-factor can be used as the verified value, subject to site quality and calibration requirements.

What to Record

For each test run, record the following information:

Troubleshooting Poor Repeatability

If the K-factor varies significantly between runs, investigate before accepting the result. Common causes include:

  • Air in the line
  • Leaks
  • Unstable flow
  • Inaccurate or poorly read collection vessel
  • Incorrect pulse counting
  • Electrical noise
  • Missed pulses
  • Fluid temperature or viscosity changes
  • Flow meter installation effects
  • Inconsistent start and stop timing
  • Flow rate outside the meter’s recommended range

Correct the issue and repeat the test.

Safety Considerations

Always follow site safety procedures and fluid-specific handling requirements. Wear appropriate PPE, provide spill containment, and ensure the collection vessel is compatible with the fluid, temperature, and expected volume.

Do not disconnect or modify pressurized piping. Isolate and depressurize equipment before making changes to the installation.

Final Thoughts

A beaker test is a simple but valuable method for checking the relationship between a flow meter’s pulse output and actual collected volume. When performed carefully, it can help confirm that the meter, sensor, electronics, and control system are working together correctly.

For critical processes, quality-controlled production, custody transfer, or applications requiring documented traceability, a formal calibration may still be required. But for many maintenance, troubleshooting, and verification tasks, a well-executed beaker test provides a practical way to improve confidence in flow measurement.

 

Technician performing a flow meter K-Factor test with beaker and equipment.
Technician conducting a flow meter K-Factor test using a beaker and specialized equipment.
Learn About The Merger